CE Marked – Available Globally
Consistent curing requires periodic monitoring of visible energy intensity or dose. The ACCU-CAL™ 50V radiometer is simple to operate and offers repeatable measurement of visible light. The ACCU-CAL 50V can measure visible light energy emitted from lightguides (3 mm, 5 mm, and 8 mm), flood systems, and conveyors.
With a spectral sensitivity from 400 to 470 nm (blue portion of the visible spectrum), the ACCU-CAL 50V measures intensities from 1 mW/cm2 to 40 W/cm2. A specially designed photo sensor assembly protects the photo sensor from the high temperatures sometimes associated with todays high-intensity spot lamps.
Take advantage of the opportunity to evaluate our light curing systems for two weeks free of charge through our Try-and-Buy program.
Looking for additional technical specifications? Check out our Resource Library or talk with our technical experts.
Get in touchProperty | Specifications |
---|---|
PTB and NIST traceable |
Looking for additional technical specifications? Check out our Resource Library or talk with our technical experts.
Get in touchBuild a complete solution or find replacement parts for your project
Limited quantities, please submit RFQ for pricing and availability.
5 mm lightguide simulator* with a standard D connection
*A lightguide simulator is used to measure direct spot lamp intensity (required to calculate lightguide transmission)
Flood to Spot Adapter Kit: Kit includes three lightguide adapters (3 mm, 5 mm, and 8 mm) and lightguide simulator*
*A lightguide simulator is used to measure direct spot lamp intensity (required to calculate lightguide transmission)
Lightguide Adapter: Fits 3 mm ID lightguides (5 mm OD)
Lightguide Adapter: Fits 5 mm ID lightguides (7 mm OD)
Lightguide Adapter: Fits 8 mm ID lightguides (10 mm OD)
ACCU-CAL™ 50V for Spot and Flood Lamps and Conveyors: Complete radiometer with lightguide adapters (3 mm, 5 mm, and 8 mm) and lightguide simulator*; includes storage/carrying case.
*A lightguide simulator is used to measure direct spot lamp intensity (required to calculate lightguide transmission)
ACCU-CAL™ 50V for Flood Lamps and Conveyors: Complete radiometer (without lightguide adapters or lightguide simulator*); includes storage/carrying case
*A lightguide simulator is used to measure direct spot lamp intensity (required to calculate lightguide transmission)
Clearance - ACCU-CAL™ 50V for Spot and Flood Lamps and Conveyors: Complete radiometer with lightguide adapters (3 mm, 5 mm, and 8 mm) and lightguide simulator*; includes storage/carrying case.
*A lightguide simulator is used to measure direct spot lamp intensity (required to calculate lightguide transmission)
Limited quantities, please submit RFQ for pricing and availability.
Clearance - ACCU-CAL™ 50V for Spot and Flood Lamps and Conveyors: Complete radiometer with lightguide adapters (3 mm, 5 mm, and 8 mm) and lightguide simulator*; includes storage/carrying case. Hours: 33011.
*A lightguide simulator is used to measure direct spot lamp intensity (required to calculate lightguide transmission)
Limited quantities, please submit RFQ for pricing and availability.