We are only accepting applications through verified recruitment websites listing our job postings (i.e. LinkedIn, Workable, Indeed, etc). Dymax will only contact potential candidates from email addresses ending in @dymax.com.
CE Marked – Available Globally
Consistent curing requires periodic monitoring of visible energy intensity or dose. The ACCU-CAL™ 50-LED radiometer is simple to operate and offers repeatable measurement of visible light. The ACCU-CAL 50-LED can measure visible light energy emitted from lightguides (3 mm, 5 mm, and 8 mm), LED flood systems, BlueWave® QX4® LED heads, and line-pattern emitters.
With a spectral sensitivity from 350 to 450 nm (blue portion of the visible spectrum), the ACCU-CAL 50-LED measures intensities from 1 mW/cm2 to 40 W/cm2. A specially designed photo sensor assembly protects the photo sensor from the high temperatures sometimes associated with today’s high-intensity spot lamps.
Take advantage of the opportunity to evaluate our light-curing systems for two weeks free of charge through our Try-and-Buy program.
Looking for additional technical specifications? Check out our Resource Library or talk with our technical experts.
Get in touchProperty | Specifications |
---|---|
Spectral Sensitivity | 350 to 450 nm |
Intensity Range | 1 mW/cm² to 40 W/cm² |
Resolution | Intensity (1 mW/cm²; to three significant digits) |
Dose (1 mJ/cm²) | |
Calibration Period | 12 months |
Operating Temperature Ranges Optometer | +5 to +40°C |
Detector | 120°C continuous, Peak 200°C |
Measurement Modes | Intensity (mW/cm²) |
Peak Intensity (mW/cm²) | |
Dose (mJ/cm²) | |
Light Sources | Lightguides (3 mm, 5 mm, and 8 mm), BlueWave® QX4® LED Wands, LED Flood Lamps, BlueWave® MX-275 |
Power Supply | Two (2) AA batteries |
Battery Life | 250 hours (automatic shutoff after 1 hour) |
Sensor Dimensions | Photo-Sensor Diameter = 9 mm |
Diameter = 37 mm | |
Thickness = 8 mm | |
Cable Length = 1 M | |
Meter Dimensions | 145 mm (Length) x 63 mm (Width) x 30 mm (Thickness) |
Looking for additional technical specifications? Check out our Resource Library or talk with our technical experts.
Get in touchBuild a complete solution or find replacement parts for your project
Limited quantities, please submit RFQ for pricing and availability.
ACCU-CAL™ 50-LED for LED Spot and Flood Units: Complete radiometer with 3 mm, 5 mm, and 8 mm lightguide adapters, lightguide simulator*, and an optical adapter for use with the BlueWave® QX4® and BlueWave® MX-275; includes storage/carrying case
*A lightguide simulator is used to measure direct spot lamp intensity (required to calculate lightguide transmissions)
ACCU-CAL™ 50-LED for LED Flood Units: Complete radiometer for LED flood and conveyor systems; includes storage/carrying case
Flood to Spot Adapter Kit: Kit includes three lightguide adapters (3 mm, 5 mm, and 8 mm) and a lightguide simulator*
*A lightguide simulator is used to measure direct spot lamp intensity (required to calculate lightguide transmissions)
Lightguide Adapter: Fits 3 mm ID lightguides (5 mm OD)
Lightguide Adapter: Fits 5 mm ID lightguides (7 mm OD)
Lightguide Adapter: Fits 8 mm ID lightguides
BlueWave® QX4® Optic Adapter Upgrade Kit: This option is for customers who already own an ACCU-CAL™ 50-LED. The kit includes the optic adapter and updated software and calibration for your existing radiometer. The customer’s radiometer must be returned to Dymax for programming and calibration.
Line Optic Adapter Upgrade Kit for the BlueWave® QX4® and BlueWave® MX-275: This option is for customers who already own an ACCU-CAL™ 50-LED. The kit includes the optic adapter and updated software to allow your radiometer to measure line-pattern systems. It also includes calibration for your existing radiometer. The customer’s radiometer must be returned to Dymax for programming and calibration.
Lightguide Simulator* (Fits all standard lightguide entrance fittings)
*A lightguide simulator is used to measure direct spot lamp intensity (required to calculate lightguide transmissions)