Available Globally, Except Europe
This UV cure oven does not emit stray UV light and can be outfitted with one, two, or four moderate-intensity 5000-EC UV flood lamps.
Looking for additional technical specifications? Check out our Resource Library or talk with our technical experts.
Get in touchProperty | Specifications |
---|---|
Maximum UVA Intensity / (320-395 nm)¹ | 200 mW/cm² |
Maximum UVA Energy / (320-395 nm) @ 5 fpm | 1.25 J/cm² (Parts: 39060, 39065, 39080, 39085) |
2.5 J/cm² (Parts: 39070, 39075, 39100, 39105) | |
Line Speed | 1 to 32 fpm |
Illuminated Width | 6 in or 12 in (depending on the number and orientation of the 5000-EC UV lamps) |
Voltage | Lamp(s) – 90V to 260V | Conveyor – 120V or 220/230V |
Vertical Clearance | 4 in (Standard) | 6 in (with 2 in riser, Part 39218) | 10 in (with 6 in riser, Part 39280) |
Overall Dimensions | 50.5 in L x 29.8 in W x 16.4 in H (128 cm x 76 cm x 72 cm) |
Bulb Life | 2,000+ hours with less than 20% degradation (typical) |
¹ | Intensity readings vary widely depending on the make and model of the radiometer. These intensities were measured with the ACCU-CAL™ 50 radiometer |
Looking for additional technical specifications? Check out our Resource Library or talk with our technical experts.
Get in touchBuild a complete solution or find replacement parts for your project
Limited quantities, please submit RFQ for pricing and availability.
One, 5000-EC, North American version (120V plug)
One, 5000-EC, North American version (220/230V plug)
Two 5000-ECs, North American version (120V plug)
Two 5000-ECs, North American version (220/230V plug)
Two 5000-EC, North American version (120V plug). These conveyors have lamps that span the full width of the conveyor.
Two 5000-EC, North American version (220/230V plug). These conveyors have lamps that span the full width of the conveyor.
Four 5000-EC, North American version (120V plug). These conveyors have lamps that span the full width of the conveyor.
Four 5000-EC, North American version (220/230V plug). These conveyors have lamps that span the full width of the conveyor.
Mercury (Optional). These bulbs are primarily designed for curing UV inks and cationic epoxies.
*Typical bulb life is 2,000+ hours with less than 20% degradation
Metal Halide (Standard)
*Typical bulb life is 2,000+ hours with less than 20% degradation
2" Riser for 6" Vertical Clearance
6" Riser for 10" Vertical Clearance
ACCU-CAL™ 50-LED for LED Flood Units: Complete radiometer for LED flood and conveyor systems; includes storage/carrying case