ACCU-CAL™ 50-LED Radiometers


For use with LED Light Curing Systems

CE Marked – Available Globally

Consistent curing requires periodic monitoring of visible energy intensity or dose. The ACCU-CAL™ 50-LED radiometer is simple to operate and offers repeatable measurement of visible light. The ACCU-CAL 50-LED can measure visible light energy emitted from lightguides (3 mm, 5 mm, and 8 mm), LED flood systems, BlueWave® QX4® LED heads, and line-pattern emitters.

With a spectral sensitivity from 350 to 450 nm (blue portion of the visible spectrum), the ACCU-CAL 50-LED measures intensities from 1 mW/cm2 to 40 W/cm2. A specially designed photo sensor assembly protects the photo sensor from the high temperatures sometimes associated with today’s high-intensity spot lamps.

  • Measures range up to 40 W/cm2
  • Sensitive at measuring stray or reflected visible light (as little as 1 mW/cm2)
  • Only one calibration per year
  • Set screw locks lightguide in place
  • PTB and NIST traceable

Take advantage of the opportunity to evaluate our light curing systems for two weeks free of charge through our Try-and-Buy program.

Specifications


Spectral Sensitivity: 350 to 450 nm

Intensity Range: 1 mW/cm2 to 40 W/cm2

Resolution:
Intensity (1 mW/cm2; to three significant digits)
Dose (1 mJ/cm2)

Calibration Period: 12 months

Operating Temperature Ranges Optometer: +5 to +40°C

Detector: 120°C continuous, Peak 200°C

Measurement Modes:
Intensity (mW/cm2)
Peak Intensity (mW/cm2)
Dose (mJ/cm2)

Light Sources:
Lightguides (3 mm, 5 mm, and 8 mm), BlueWave® QX4® LED Wands, LED Flood Lamps, BlueWave® MX-275

Power Supply: Two (2) AA batteries

Battery Life: 250 hours (automatic shutoff after 1 hour)

Sensor Dimensions:
Photo-Sensor Diameter = 9 mm
Diameter = 37 mm
Thickness = 8 mm
Cable Length = 1 M

Meter Dimensions:
145 mm (Length) x 63 mm (Width) x 30 mm (Thickness)

Radiometers & Accessories


Part # Product/Description
40505 ACCU-CAL™ 50-LED for LED Spot and Flood Units: Complete radiometer with 3 mm, 5 mm, and 8 mm lightguide adapters, lightguide simulator*, and an optical adapter for use with the BlueWave® QX4® and BlueWave® MX-275; includes storage/carrying case
40519 ACCU-CAL™ 50-LED for LED Flood Units: Complete radiometer for LED flood and conveyor systems; includes storage/carrying case
39554 Flood to Spot Adapter Kit: Kit includes three lightguide adapters (3 mm, 5 mm, and 8 mm) and a lightguide simulator*
39556 Lightguide Adapter: Fits 3 mm ID lightguides (5 mm OD)
39557 Lightguide Adapter: Fits 5 mm ID lightguides (7 mm OD)
39558 Lightguide Adapter: Fits 8 mm ID lightguides
38408 Lightguide Simulator* (Fits all standard lightguide entrance fittings)
42218 BlueWave® QX4® Optic Adapter Upgrade Kit: This option is for customers who already own an ACCU-CAL™ 50-LED. The kit includes the optic adapter and updated software and calibration for your existing radiometer. The customer’s radiometer must be returned to Dymax for programming and calibration.
43383 Line Optic Adapter Upgrade Kit for the BlueWave® QX4® and BlueWave® MX-275: This option is for customers who already own an ACCU-CAL™ 50-LED. The kit includes the optic adapter and updated software to allow your radiometer to measure line-pattern systems. It also includes calibration for your existing radiometer. The customer’s radiometer must be returned to Dymax for programming and calibration.

*A lightguide simulator is used to measure direct spot lamp intensity (required to calculate lightguide transmissions)

Features


  • Simple to operate
  • Accurate measurement of curing energy
  • Can measure energy levels emitted from lightguides (3 mm, 5 mm, and 8 mm), BlueWave® QX4® LED heads, and LED flood lamps.
  • Possesses a spectral sensitivity range of 350 – 450 nm
  • Intensity measurement from 1 mW/cm2 to 40 W/cm2
  • Ideal for measuring LED curing source energy levels
  • Specially designed photo-sensor assembly provides repeatable measurements and protection from high temperatures
ACCU-CAL 50-LED Radiometer